FS-6 Foot Switches with Emergency Stop |
Features: This is a special design foot switch with two stage momentary contacts.There are noticable resistance between stage one and stage two when pressing the pedal without reaching the pressure point,the foot switch operates in the normal model.In case of emergency,the user depresses the foot pedal even harder instead of releasing the pedal.This special safety foot switch will break electrical contact and locked.The manual reset button need to be pushed before it can operate in normal model.This can quickly prevent damage to the machine or injury to human life.
|
Installation dimensions:
|
Specifications: Operating Frequency: 60 ops/min
Insulation Resistance: >100mΩ@500VDC
Contact Resistance: <25mΩ
Rated Current/Voltage 10A/600V AC A600/AC15 Q300/DC13
Inrush Current Complies with IEC947-5-1:AC15/DC 13
Dielectric Strength: 1000VAC for 1 min between current carrying parts
2500VAC for 1 min between non-current carrying parts
Service Life: Mechanically 1.0×106(operations)
Electrically 5×105 (operations)
Operating Temperature:-30~+80℃(-22~176°F)
Degree of Protection: IP65 (IP68 available on request)
|
TRADEMARK INFORMATION:
All trademarks, trade names, or logos mentioned or used are the property of their respective owners.
-
For example:FS-61 |
-G |
-SP |
-A |
-S |
-K |
-A |
-R |
Single pedal |
Guarding options |
Contact Block Type |
Special Features |
Switch Configuration |
option |
Conduit Type |
|
|
blank:No Guarded |
SP: snap action |
blank |
blank:SPDT |
blank |
A: 1/2NPT |
WITH RESET FUNCTION |
|
G: Fully Guarded |
SL:slow action
break before make
|
A: Anti-tripped |
T:DPDT |
K:Gold plated contactcs |
B:PG13.5 |
|
|
|
SL1:slow action
make before break
|
|
S: 2 stages |
|
C:M20x1.5 |
|
Operating sequence:<br>
"OFF" Step 1:the pedal is not depressed.The contacts are open.The machine is turned off.<br>
"ON" Step 2:To start the machine,the pedal must be depressed until the "pressure point",where resistance is noticeable.<br>
"EMERGENCY-OFF" Step 3: In an emergency,if the pedal is depressed beyond the pressure point,the machine will stop.<br>
Beyond the pressure point,the contacts are locked in the "OFF:-Position.The machine cannot operate at
this time.Note:The machine can also be stopped,by releasing the pedal in stead of depressing harder (Black to step 1)<br>
"RESET" Step4: The push button on the side of the foot switch must be pushed by hand to enable the foot switch to start the machine function again.<br>
"ON" Step5:Return to condition described in Step 2.
TRADEMARK INFORMATION:
All trademarks, trade names, or logos mentioned or used are the property of their respective owners.
-
TRADEMARK INFORMATION:
All trademarks, trade names, or logos mentioned or used are the property of their respective owners.
-
TRADEMARK INFORMATION:
All trademarks, trade names, or logos mentioned or used are the property of their respective owners.
|
|